Table Description:
This table gives empirical magnitude limits for G and BP bands derived from Gaia DR2 with G < 20.7 mag for HEALPixels of 7 (scale roughly ~0.5 degrees). For each band we have 4 different variants:
For BP mag limits we also require that BP is available. The magnitude limits are approximated by the mode of the magnitude distribution in a specific HEALpix. Since this mode estimator is prone to Poisson noise in low density areas we report the magnitude limits in two flavours:
except that in healpixel with a stellar density below 1e5 sources per square degree the limit is arbitrarily set to 20.7 mag. These magnitude limits were created using the gdr2_completeness package and users are encouraged to create custom-made magnitude limits with specific conditions, e.g. RVS sample with good parallaxes.
This table is available for ADQL queries and through the TAP endpoint.
Resource Description:
For a list of all services and tables belonging to this table's resource, see Information on resource 'Gaia early DR3 Mock Catalogue (gedr3mock)'
Resource Reference URL: http://dc.zah.uni-heidelberg.de/tableinfo/gedr3mock.main
This table has an associated publication. If you use data from it, it may be appropriate to reference 2020PASP..132g4501R (ADS BibTeX entry for the publication) either in addition to or instead of the service reference.
To cite the table as such, we suggest the following BibTeX entry:
@MISC{vo:gedr3mock_maglim, year=2019, title={Gaia early DR3 Mock Catalogue (gedr3mock)}, author={Rybizki, J. and Demleitner, M. and Bailer-Jones, C. and Tio, P. D. and Cantat-Gaudin, T. and Fouesneau, M. and Chen, Y. and Andrae, R. and Girardi, L. and Sharma, S.}, url={https://dc.zah.uni-heidelberg.de/tableinfo/gedr3mock.maglim_7}, howpublished={{VO} resource provided by the {GAVO} Data Center}, doi = {10.21938/dBrplG8I1KR7RyfkMXTyYA} }
Sorted by DB column index. [Sort alphabetically]
Name | Table Head | Description | Unit | UCD |
---|---|---|---|---|
hpx | HEALPix | Level 7 HEALPix for which the magnitude limit applies. | N/A | pos.healpix |
maglim_g | Mode G | The mode of the G magnitude distribution in the respective HEALPix | mag | instr.sensitivity |
starcount_g | #Stars | The number of stars in the respective HEALPix bin with G<20.7 | N/A | meta.number |
maglim_g_density_threshold | Mode G HD | The mode of the G magnitude distribution in the respective HEALPix. In HEALPixes with less than 1e5 stars per square degree the limit is set to 20.7 mag. This should reduce the noise of the mode estimator due to Poisson noise in low density areas. | mag | instr.sensitivity |
maglim_g_parallax | Mode G | The mode of the G magnitude distribution in the respective HEALPix when also requiring a parallax measurement | mag | instr.sensitivity |
starcount_g_parallax | #Stars | The number of stars in the respective HEALPix bin with G<20.7 and parallax measurement | N/A | meta.number |
maglim_g_parallax_density_threshold | Mode G HD | The mode of the G magnitude distribution in the respective HEALPix when also requiring a parallax measurement. In HEALPixes with less than 1e5 stars per square degree the limit is set to 20.7 mag. This should reduce the noise of the mode estimator due to Poisson noise in low density areas. | mag | instr.sensitivity |
maglim_g_color | Mode G | The mode of the G magnitude distribution in the respective HEALPix when also requiring a BP and RP measurement | mag | instr.sensitivity |
starcount_g_color | #Stars | The number of stars in the respective HEALPix bin with G<20.7 and BP and RP measurement | N/A | meta.number |
maglim_g_color_density_threshold | Mode G HD | The mode of the G magnitude distribution in the respective HEALPix when also requiring a BP and RP measurement. In HEALPixes with less than 1e5 stars per square degree the limit is set to 20.7 mag. This should reduce the noise of the mode estimator due to Poisson noise in low density areas. | mag | instr.sensitivity |
maglim_g_parallax_color | Mode G | The mode of the G magnitude distribution in the respective HEALPix when also requiring a parallax and BP and RP measurement | mag | instr.sensitivity |
starcount_g_parallax_color | #Stars | The number of stars in the respective HEALPix bin with G<20.7 and parallax and BP and RP measurement | N/A | meta.number |
maglim_g_parallax_color_density_threshold | Mode G HD | The mode of the G magnitude distribution in the respective HEALPix when also requiring a parallax and BP and RP measurement. In HEALPixes with less than 1e5 stars per square degree the limit is set to 20.7 mag. This should reduce the noise of the mode estimator due to Poisson noise in low density areas. | mag | instr.sensitivity |
maglim_bp | Mode BP | The mode of the BP magnitude distribution in the respective HEALPix | mag | instr.sensitivity |
starcount_bp | #Stars | The number of stars in the respective HEALPix bin with G<20.7 | N/A | meta.number |
maglim_bp_density_threshold | Mode BP HD | The mode of the BP magnitude distribution in the respective HEALPix. In HEALPixes with less than 1e5 stars per square degree the limit is set to 20.7 mag. This should reduce the noise of the mode estimator due to Poisson noise in low density areas. | mag | instr.sensitivity |
maglim_bp_parallax | Mode BP | The mode of the BP magnitude distribution in the respective HEALPix when also requiring a parallax measurement | mag | instr.sensitivity |
starcount_bp_parallax | #Stars | The number of stars in the respective HEALPix bin with G<20.7 and parallax measurement | N/A | meta.number |
maglim_bp_parallax_density_threshold | Mode BP HD | The mode of the BP magnitude distribution in the respective HEALPix when also requiring a parallax measurement. In HEALPixes with less than 1e5 stars per square degree the limit is set to 20.7 mag. This should reduce the noise of the mode estimator due to Poisson noise in low density areas. | mag | instr.sensitivity |
maglim_bp_color | Mode BP | The mode of the BP magnitude distribution in the respective HEALPix when also requiring a BP and RP measurement | mag | instr.sensitivity |
starcount_bp_color | #Stars | The number of stars in the respective HEALPix bin with G<20.7 and BP and RP measurement | N/A | meta.number |
maglim_bp_color_density_threshold | Mode BP HD | The mode of the BP magnitude distribution in the respective HEALPix when also requiring a BP and RP measurement. In HEALPixes with less than 1e5 stars per square degree the limit is set to 20.7 mag. This should reduce the noise of the mode estimator due to Poisson noise in low density areas. | mag | instr.sensitivity |
maglim_bp_parallax_color | Mode BP | The mode of the BP magnitude distribution in the respective HEALPix when also requiring a parallax and BP and RP measurement | mag | instr.sensitivity |
starcount_bp_parallax_color | #Stars | The number of stars in the respective HEALPix bin with G<20.7 and parallax and BP and RP measurement | N/A | meta.number |
maglim_bp_parallax_color_density_threshold | Mode BP HD | The mode of the BP magnitude distribution in the respective HEALPix when also requiring a parallax and BP and RP measurement. In HEALPixes with less than 1e5 stars per square degree the limit is set to 20.7 mag. This should reduce the noise of the mode estimator due to Poisson noise in low density areas. | mag | instr.sensitivity |
Columns that are parts of indices are marked like this.
The following services may use the data contained in this table:
VO nerds may sometimes need VOResource XML for this table.